Effect of Triazine Comonomer Substitution on the Structure and Glass Transition Temperature of Monomethacrylate-based Resin Polymer: An In Vitro Study
Ravivarman, Chandramohan and Ajay, Ranganathan and Rakshagan, Vikraman and Queenalice, Arul and Vinothkumar, Sengottaiyan and Saravanadinesh, Paulpandian (2022) Effect of Triazine Comonomer Substitution on the Structure and Glass Transition Temperature of Monomethacrylate-based Resin Polymer: An In Vitro Study. The Journal of Contemporary Dental Practice, 23 (2). pp. 202-207. ISSN 1526-3711
NMR, Tg, FESEM-EDX article.pdf
Download (1MB)
Abstract
Aim and objectives: The present research aimed to characterize and deduce the structure of a novel denture base copolymer containing antimicrobial triazine comonomer by nuclear magnetic resonance (NMR) and energy-dispersive X-ray (EDX) spectroscopies. Also, it aimed to evaluate the glass transition temperature (Tg) with the addition of TATA at different concentrations.
Materials and methods: The trial groups G10 and G20 were thermo-polymerized with triazine comonomer, whereas the control group G0 was polymerized without the triazine. NMR and EDX spectroscopies assessed copolymerization along with deducing elemental composition in
mass %. The surface topographies were observed through field-emission scanning electron microscopy (FESEM). The Tg of the resultant copolymer was examined by differential scanning calorimetry. Pertinent statistical tests with relevant multiple comparison tests were exercised to compare the mean Tg of the groups.
Results: The configuration of a new copolymer containing triazine comonomer was manifested with additional protons and carbon atoms. Nitrogen was detected in the EDX spectroscopy of the trial groups. The Tg of the new copolymer was higher than the G0. The triazine comonomer in the copolymer at 20% concentration exhibited the highest Tg.
Conclusion: The triazine comonomer substitution produced a novel denture base copolymer with enhanced Tg.
Clinical significance: The novel denture base copolymer may possess enhanced biomechanical properties due to the TATA’s cross-linking capability. Nevertheless, the antimicrobial property of the triazine comonomer incorporated in the denture base composition might be beneficial in inhibiting the microbial colonization on the denture’s surface.
Keywords: Antimicrobial, Copolymer, Denture base, Glass transition temperature, Triazine.
| Item Type: | Article |
|---|---|
| Subjects: | No Subjects |
| Divisions: | Prosthodontics and Crown and Bridge |
| Depositing User: | Unnamed user with email techsupport@mosys.org |
| Date Deposited: | 27 Oct 2026 07:19 |
| Last Modified: | 27 Oct 2026 07:19 |
| URI: | https://ir.vdcw.ac.in/id/eprint/353 |
