Influence of Abutment Type on Stress Distribution around Single Implant with Cantilever Prosthesis by Means of Photoelastic Analysis: An In Vitro Study
Rakshagan, Vikraman and Ajay, Ranganathan and Kolliboyana, Jai Krishna Srikanth and Hariprasad, Mohan Prasanna and Ramesh, K and Thakkalapati, Parthasaradhi (2025) Influence of Abutment Type on Stress Distribution around Single Implant with Cantilever Prosthesis by Means of Photoelastic Analysis: An In Vitro Study. World Journal of Dentistry, 16 (8). pp. 702-708. ISSN 0976-6006
2 Rakshagan.pdf
Download (487kB)
Abstract
Aim: To evaluate the influence of standard abutment on stress distribution around a single implant with a cantilever prosthesis using photoelastic analysis in a patient-simulated mandibular three-dimensional (3D) photoelastic model.
Materials and methods: A photoelastic model with eight implants (n = 8) in relation to 36 was fabricated. Screw-retained cantilever prosthesis with wide platform abutment (Group I) (n = 4) and screw-retained cantilever prosthesis with standard platform abutment (Group II) (n = 4) were connected to the implant and loaded with 6, 7, and 8 kg. The load was applied to both the cantilevered premolar and molar area of the prosthesis simultaneously. The photoelastic model was analyzed in a circular polariscope. The highest fringe order, depicting stress intensity, was recorded and described for the coronal, middle, and apical third regions around the implant. Data were tabulated and subjected to a qualitative descriptive analysis.
Results: Photoelastic analysis showed that Group I (wide platform abutment) exhibited high crestal stress, with stress pocketing increasing from 6 kg (237.20 N) to 8 kg (316.20 N). In contrast, Group II (platform-switching) demonstrated more uniform stress distribution, with no stress pocketing at 6 and 7 kg, and only mild pocketing at 8 kg. Independent t-tests confirmed a significant difference between groups at all loads (p < 0.05), indicating that platform-switching reduces crestal stress and enhances biomechanical performance.
Conclusion: The implant-supported screw-retained cantilever prosthesis with wide platform abutment showed higher stress distribution in the coronal zone compared to that with standard platform abutment (platform-switching) upon loading. The increase in stress intensity was proportional to the increase in load application.
Clinical significance: The findings highlight the importance of selecting the appropriate abutment design for implant-supported cantilever prostheses to minimize stress distribution on the implant and surrounding bone. The results may guide clinicians in optimizing prosthesis design for better long-term outcomes.
Keywords: Dental implant loading, Dental implant, Dental prosthesis implant-supported, Dental prosthesis, Single tooth.
| Item Type: | Article |
|---|---|
| Subjects: | No Subjects |
| Divisions: | Prosthodontics and Crown and Bridge |
| Depositing User: | Unnamed user with email techsupport@mosys.org |
| Date Deposited: | 27 Oct 2026 05:20 |
| Last Modified: | 27 Oct 2026 05:20 |
| URI: | https://ir.vdcw.ac.in/id/eprint/315 |
